Project
LOGIN
Search for:
Superintendents
Chancellors
Head Masters
Facilities / Property Managers
Architects
Engineers
Contractors
Directors
Facilities / Property Managers
Architects
Engineers
Contactors
Procurement Managers
Project Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Owners
Facilities / Property Managers
Architects
Engineers
Contractors
Owners
Facilities / Property Managers
Architects
Engineers
Contractors
General Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Procurement Managers
Port Engineers
Ship's Crew
Architects
Engineers
Contractors
Owners
Project Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Education
Healthcare
Government
Hotels & Apartments
Office Buildings
Industrial & Manufacturing
Navy & Marine
Other
Benchmark 750 & 1000
Benchmark 1.5 Low NOx Boiler
Benchmark 2.0 Low NOx Boiler
Benchmark 3.0 Low NOx Boiler
Esteem 399 Low NOx Wall Hung Boiler
Esteem Cascade System
Benchmark
Esteem Boilers
KC-1000 Boiler
Modulex Boilers
Water-Wizard B+II
A+ (Model #SW1A+)
B+ (Model #SW1B+)
E+ (Model #WW3E+)
Innovation 600
Innovation 800
Innovation 1060
Single Wall
Double Wall
Model #SWDW24
Model #SWDW45
Model #SWDW68
Model #WWDW24
Model #WWDW45
Model #WWDW68
Steam-to-Water
Water-to-Water
Helitherm Indirect Heaters
Innovation Direct Fired Water Heaters
KC-1000 Gas Fired Heater
SmartPlate Heaters
U-Tube Double Wall Heaters
Model #SS1B+
Model #SS3CE+
Model #WS3E+
C-More Unit Controller
E8 Controller
Electronic Controls System
AERCO / ProtoNode Gateways
BMS II Model 5R5-384
Boiler Valve Controller
Communications Gateway
Modulex Pump Kits
X100 Corrosion Inhibitor
X200 Noise Reducer
X400 System Restorer
X500 Inhibited Antifreeze
AERCO Buffer Tanks
AERCO DHW Storage Tanks
Belimo F6 HDU Butterfly Motorized Valve
AERClean Air Filtration System
Communications Equipment
Condensate Neutralizer Kit
Hydraulic Separator
Optional Controls
Pump Products
Sentinel Products
Steam Traps
Tank Products
Valve Products
Selection Wizard
Boilers
Water Heaters
Clean Steam Generators
Integrated Controls
Accessories
Case Studies
Document Index
AERCO HydroSkrub
Benchmark Maintenance Kits
KC1000 Maintenance Kits
Modulex Maintenance Kits
Direct Fired SST
SST Recertification
Modulex Boilers
End User
Maintenance
Technical Training
O&M Manuals
Equipment Start-up & Registration
AERCO Technologies
AERCO Green Initiative
Importance of Modulation
Turndown vs. Valve Position
Condensing Flue Gases
Seasonal Performance
Comparing Efficiency
Self-Descaling Coil
Subcooling Steam
Rep Locator
Home
Markets
Products
Service & Support
Technologies
How to Buy
Connect with us
Home
>
Technologies
>
Importance of Modulation
The Importance of Modulation
In general, modulation refers to the ability to adjust a boiler's or water heater's firing rate (input) to meet the heating demand (output) of the system.
AERCO equipment utilizes a fully modulating design that precisely matches firing rate to actual building demand. A 2.0 million BTU/hr. capacity Benchmark boiler can run with as little as 100,000 BTU/hr., or 5%, input. Likewise, the 1.0 million BTU/hr. KC1000 line maintains steady combustion with only 50,000 BTU/hr. input. Drawing only enough fuel to meet actual load changes, each unit will gradually increase its capacity – in precise 1% increments – up to 100% capacity.
Not only is less fuel burned as a result of modulating input, but also heat transfer is enhanced when the AERCO units operate at "part load." Constant operation maintains temperatures within the heat exchanger, yet the reduced input increases the time these combustion gases are in contact with the heat exchanger surface, promoting greater energy transfer and cooler exhaust gases. AERCO equipment features an inverse efficiency curve performing best at lowest loads.
Since the majority of a boiler's operating hours will be under "part load conditions," modulating units promise greater seasonal efficiency.
BMS and Modulation
AERCO's inverse efficiency profile can be fully leveraged by carefully coordinating the operation of multiple units by using the AERCO Boiler Management System. Put simply, it requires less energy for a group of modulating boilers, each firing at a lower load, to heat a building than for a single boiler operated at full or high fire to carry the entire workload.
AERCO's BMS regulates the operation of multiple Benchmark or KC1000 installations, giving each unit firing instructions to maximize the efficiency of the plant as a whole as loads change throughout the day. Operating hours are also distributed evenly across all units, always alternating the lead boiler so that no particular unit receives more work over time than the others do.
Where Conventional Equipment Falls Short
The oldest boiler designs have only one level of power – 100%. They are either on or off. This creates cycling losses each time the unit shuts down; the heat exchanger cools off and must be fully "reheated" before heat transfer can begin. (See "
The Impact of Heat Soak
.")
Once the unit restarts, the 100% firing rate may be far more than what is required to meet the building's load.
While newer burners and boiler designs incorporate 5:1 or 3:1 turndown ratios, limited firing rates still result in some wasteful overshooting or cycling losses.