init
Project
LOGIN
Search for:
Superintendents
Chancellors
Head Masters
Facilities / Property Managers
Architects
Engineers
Contractors
Directors
Facilities / Property Managers
Architects
Engineers
Contactors
Procurement Managers
Project Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Owners
Facilities / Property Managers
Architects
Engineers
Contractors
Owners
Facilities / Property Managers
Architects
Engineers
Contractors
General Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Procurement Managers
Port Engineers
Ship's Crew
Architects
Engineers
Contractors
Owners
Project Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Education
Healthcare
Government
Hotels & Apartments
Office Buildings
Industrial & Manufacturing
Navy & Marine
Other
Benchmark 750 & 1000
Benchmark 1.5 Low NOx Boiler
Benchmark 2.0 Low NOx Boiler
Benchmark 3.0 Low NOx Boiler
Esteem 399 Low NOx Wall Hung Boiler
Esteem Cascade System
Benchmark
Esteem Boilers
KC-1000 Boiler
Modulex Boilers
Water-Wizard B+II
A+ (Model #SW1A+)
B+ (Model #SW1B+)
E+ (Model #WW3E+)
Innovation 600
Innovation 800
Innovation 1060
Single Wall
Double Wall
Model #SWDW24
Model #SWDW45
Model #SWDW68
Model #WWDW24
Model #WWDW45
Model #WWDW68
Steam-to-Water
Water-to-Water
Helitherm Indirect Heaters
Innovation Direct Fired Water Heaters
KC-1000 Gas Fired Heater
SmartPlate Heaters
U-Tube Double Wall Heaters
Model #SS1B+
Model #SS3CE+
Model #WS3E+
C-More Unit Controller
E8 Controller
Electronic Controls System
AERCO / ProtoNode Gateways
BMS II Model 5R5-384
Boiler Valve Controller
Communications Gateway
Modulex Pump Kits
X100 Corrosion Inhibitor
X200 Noise Reducer
X400 System Restorer
X500 Inhibited Antifreeze
AERCO Buffer Tanks
AERCO DHW Storage Tanks
Belimo F6 HDU Butterfly Motorized Valve
AERClean Air Filtration System
Communications Equipment
Condensate Neutralizer Kit
Hydraulic Separator
Optional Controls
Pump Products
Sentinel Products
Steam Traps
Tank Products
Valve Products
Selection Wizard
Boilers
Water Heaters
Clean Steam Generators
Integrated Controls
Accessories
Case Studies
Document Index
AERCO HydroSkrub
Benchmark Maintenance Kits
KC1000 Maintenance Kits
Modulex Maintenance Kits
Direct Fired SST
SST Recertification
Modulex Boilers
End User
Maintenance
Technical Training
O&M Manuals
Equipment Start-up & Registration
AERCO Technologies
AERCO Green Initiative
Importance of Modulation
Turndown vs. Valve Position
Condensing Flue Gases
Seasonal Performance
Comparing Efficiency
Self-Descaling Coil
Subcooling Steam
Rep Locator
Home
Markets
Products
Service & Support
Technologies
How to Buy
Connect with us
Home
>
Products
>
Water Heaters
>
Helitherm Indirect Heaters
>
E+ (Model #WW3E+)
OVERVIEW
E+ (Model #WW3E+)
Recommended for all water-to-water applications.
FEATURES & BENEFITS
OPTIONS & ACCESSORIES
TECHNICAL DOCUMENTS & SPECIFICATIONS
MANUALS
CASE STUDIES
Click here for details
AERCO's unique feed-forward monitoring system and fully modulating control valves maintain +/-4°F water temperatures under the diversified load patterns of commercial domestic hot water applications. Performing with 99% thermal efficiency, the unique helical coil heat exchanger design of these single wall heaters is self-descaling to maximize longevity and reduce maintenance. Configurations are available for both low temperature & pressure and high temperature & pressure boiler water applications. All units are compatible with low or high steam pressures and do not require a storage tank, trap or associated maintenance.
PRODUCT OPTIONS
Packaged Heater
- Shipped completely assembled and ready for immediate hook-up; includes heat exchanger, your choice of electronic 2-way valve or pneumatic 2 or 3 way valve, and full controls package.
Bare Heater
- Heat exchanger only; insulation optional.
Materials of Construction
Standard: Copper or copper alloy wetted surfaces
Optional: 0.065" thick copper or copper-nickel tubing
Optional: Upgrade to 316L stainless-steel wetted parts
ACCESSORIES
Domestic Water Storage Tank
- AERCO storage tanks are ASME certified glass-lined pressure vessels designed for use with instantaneous water heaters. When contending with challenging applications they assure consistent hot water service during peak demands. The AERCO storage tanks are available in stratified or accumulator storage configurations.
Pressure Gradient Monitoring (PGM) System
- Offered in lieu of double wall construction where codes allow.
Settings for Pressure Relief Valve
Standard: 150 PSIG, 212°F P&T
Optional: 230 PSIG for high-rise applications
CONTROLS
Electronic Controls
- AERCO's exclusive electronic control system combines a control box assembly with all circuitry, a flow meter installed at the cold water inlet for feed-forward sensing, feedback sensors and voltage regulator. To maintain optimal temperature control, the system utilizes PID algorithms to monitor outlet temperature and change control valve position. Easy-to-use digital displays are protected by clear-cover enclosure which can be locked. The system also includes an overtemp limit switch and water solenoid valve to function as a secondary water relief valve in an over-temperature condition.
Modbus Communications
- Optional control board supports remote control and integration via Modbus protocol to Building Automation or Energy Management Software via RS-232 or RS-485 port.
Communications Gateway
- Optional accessory supports integration with BACnet, LonWorks and N2 systems. Available only for heaters equipped with Modbus control board.
Pneumatic Controls
- AERCO's exclusive Loadalert system continuously monitors water temperature and flow and modulates the flow of steam through the control valve and into the coils. Control panel includes pneumatic controller and dual solenoid valve over-temperature limit system. (One solenoid to disable steam control valve; One solenoid to perform as a secondary water relief valve.) Power on/tripped status lights, liquid-filled remote capillary thermometer and compound steam pressure gauge also included.
Dry Contacts
- Optional for remote "High Limit Tripped Status" indication.
Literature & Performance Data
File Type
View
Save
File Type
View
Save
Electronic Control Package Sales Sheet
.pdf
•
•
WW3E+ Technichal Data Sheet
.pdf
•
•
Electronic Control Package Data Sheet
.pdf
•
•
Valves
Pneumatic Valve Tech Data Sheet
.pdf
•
•
Electronic Control Valve Data Sheet
.pdf
•
•
Sizing & Application Guidelines
File Type
View
Save
File Type
View
Save
Applications & Sizing Guidelines HE-2040
.pdf
•
•
Guidelines for On/Off & Solenoid-Type Fixtures
.pdf
•
•
Steam Trap Guidelines (A701.0)
.pdf
•
•
Laundry Systems Sizing
Technical Bulletin (HE-2020)
.pdf
•
•
Valves
Sizing Data
.pdf
•
•
Product & Component Drawings
File Type
View
Save
File Type
View
Save
Dimensional Drawings
Low Press/Temp Pkg. with 2-Way Pneumatic Valve (AP-A-584)
.pdf
•
•
.dwg
•
•
Low Press/Temp Pkg. with 2-Way Electric Valve (AP-A-790)
.pdf
•
•
.dwg
•
•
Low Press/Temp Pkg. with 3-way Pneumatic Mixing Valve (AP-A-583)
.pdf
•
•
.dwg
•
•
Hi Press/Temp Pkg. with 2-way Pneumatic Valve
.pdf
•
•
.dwg
•
•
Bare Heater (AP-A-684)
.pdf
•
•
.dwg
•
•
Bare Heater with Side Flanges (AP-A-633)
.pdf
•
•
.dwg
•
•
Valves
Pneumatic Valve 1-2" Exploded View
.pdf
•
•
Pneumatic Valve 2.5"- 4" Exploded View
.pdf
•
•
Pneumatic Valve with PGM Box
.pdf
•
•
.dwg
•
•
Electronic Valve 1-2" Exploded View
.pdf
•
•
Electronic Valve 2.5"- 4" Exploded View
.pdf
•
•
Flowrite 599 Three Way Valve (VA-11)
.pdf
•
•
Installation & Piping Drawings
File Type
View
Save
File Type
View
Save
Single Heater
2-way Valve
.pdf
•
•
.dwg
•
•
2-Way & Accumulator
.pdf
•
•
.dwg
•
•
2-Way & Stratified
.pdf
•
•
.dwg
•
•
3-Way, Low Temp
.pdf
•
•
.dwg
•
•
3-Way, Low Temp, Stratified
.pdf
•
•
.dwg
•
•
Multiple Heaters in Parallel
2-Way Valve
.pdf
•
•
.dwg
•
•
2-Way & Accumulator
.pdf
•
•
.dwg
•
•
2-Way & Stratified
.pdf
•
•
.dwg
•
•
3-Way, Low Temp
.pdf
•
•
.dwg
•
•
3-Way, Low Temp, Stratified
.pdf
•
•
.dwg
•
•
Controls
File Type
View
Save
File Type
View
Save
Pneumatic Control Box Layout with PGM
.pdf
•
•
.dwg
•
•
Electronic Control Box Wiring Diagram (SD-A-667)
.pdf
•
•
.dwg
•
•
Electronic Control Box Layout
.pdf
•
•
.dwg
•
•
Pneumatic Control Box Layout
.pdf
•
•
.dwg
•
•
Wiring
File Type
View
Save
File Type
View
Save
Temperature Limiting System
With Remote Relay Alarm
.pdf
•
•
.dwg
•
•
Wiring Diagram
.pdf
•
•
.dwg
•
•
With PGM System & 2-Way Control Valve
.pdf
•
•
.dwg
•
•
With PGM System & 3-Way Motorized Ball Valve
.pdf
•
•
.dwg
•
•
Specifications
File Type
View
Save
File Type
View
Save
WW3E+ Spec with Pneumatic Valve
.doc
•
•
WW3E+ Spec with Electronic Valve
.doc
•
•
Standard Warranty
File Type
View
Save
File Type
View
Save
A+, B+, Wizard, E+ Warranty
.pdf
•
•
Operation & Maintenance
File Type
View
Save
File Type
View
Save
ECS Retrofit Instructions (SB6-02)
.pdf
•
•
Packaged "E+" Water-to-Water Heater HE-108
.pdf
•
•
Electronic Controls System O&M (AC-105)
.pdf
•
•
Pneumatic Temperature Controller (AC-103)
.pdf
•
•
Instructions
File Type
View
Save
File Type
View
Save
Adding a Communications Board to ECS (SB6-03)
.pdf
•
•
AERCO Water Heaters: Just What the Doctor Ordered for New Jersey’s Largest Medical Center