init
Project
LOGIN
Search for:
Superintendents
Chancellors
Head Masters
Facilities / Property Managers
Architects
Engineers
Contractors
Directors
Facilities / Property Managers
Architects
Engineers
Contactors
Procurement Managers
Project Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Owners
Facilities / Property Managers
Architects
Engineers
Contractors
Owners
Facilities / Property Managers
Architects
Engineers
Contractors
General Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Procurement Managers
Port Engineers
Ship's Crew
Architects
Engineers
Contractors
Owners
Project Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Education
Healthcare
Government
Hotels & Apartments
Office Buildings
Industrial & Manufacturing
Navy & Marine
Other
Benchmark 1.5 Low NOx Boiler
Benchmark 2.0 Low NOx Boiler
Benchmark 2.0 Standard or Dual Fuel Boiler
Benchmark 3.0 Low NOx Boiler
Esteem 399 MBH Low NOx Wall Hung Boiler
Benchmark Boilers
Esteem Boilers
KC-1000 Boiler
Modulex Boilers
Water-Wizard B+II
A+ (Model #SW1A+)
B+ (Model #SW1B+)
E+ (Model #WW3E+)
Single Wall
Double Wall
Model #SWDW24
Model #SWDW45
Model #SWDW68
Model #WWDW24
Model #WWDW45
Model #WWDW68
Steam-to-Water
Water-to-Water
Helitherm Indirect Heaters
KC-1000 Gas Fired Heater
SmartPlate Heaters
U-Tube Double Wall Heaters
Model #SS1B+
Model #SS3CE+
Model #WS3E+
C-More Unit Controller
E8 Controller
Electronic Controls Package
BMS II Model 5R5-384
Boiler Valve Controller
Communications Gateway
BMS Model 168
Combination Control Panel
Modulex Pump Kits
AERCO Buffer Tanks
AERCO DHW Storage Tanks
Hydraulic Separator
Optional Controls
Pump Products
Tank Products
Energy Calculator
Selection Wizard
Boilers
Water Heaters
Clean Steam Generators
Integrated Controls
Accessories
Technical Tools
Case Studies
Document Index
AERCO HydroSkrub
Benchmark Maintenance Kits
KC1000 Maintenance Kits
Modulex Maintenance Kits
Direct Fired SST
SST Recertification
Modulex Boilers
End User
Maintenance
Technical Training
O&M Manuals
Equipment Start-up & Registration
AERCO Technologies
AERCO Green Initiative
Importance of Modulation
Turndown vs. Valve Position
Condensing Flue Gases
Seasonal Performance
Comparing Efficiency
Self-Descaling Coil
Subcooling Steam
Rep Locator
Home
Markets
Products
Service & Support
Technologies
How to Buy
Markets
Education
Healthcare
Government
Hotels & Apartments
Office Buildings
Industrial & Manufacturing
Navy & Marine
Other
Home
>
Products
>
Boilers
>
Benchmark Boilers
>
Benchmark 2.0 Standard or Dual Fuel Boiler
OVERVIEW
Benchmark 2.0 Standard or Dual Fuel Boiler
Backed by field-proven performance for more than 10 years, gas-fired Benchmark boilers reduce total project and lifecycle costs while delivering energy efficiency, quiet acoustics and lower operating costs.
Ideal for all hydronic heating applications, they are especially suitable for applications utilizing cooler water temperatures such as water source heat pump projects.
Listed in the
GreenSpec directory of green building products
FEATURES & BENEFITS
OPTIONS & ACCESSORIES
PRODUCT SPECIFICATIONS
TECHNICAL DOCUMENTS
O & M MANUALS
CASE STUDIES
The Benchmark boiler can also support natural gas with propane back-up applications to take advantage of discounted "interruptible" gas rates or where dual fuel capability is mandated.
The condensing heat exchanger design is built to withstand thermal shock and eliminates the need for boiler pumping equipment to lower the size, cost, and operating expense of components throughout the entire heating loop. The forced draft, modulating burner operates with 20:1 turndown to deliver up to 98% thermal efficiency while simplifying the venting system.
Each 2 million BTU/hr. stainless steel unit fits through 30" doorways and occupies a footprint of 12 sq. ft. with zero side-wall clearance for easy installation. Removable enclosure panels, and rear access to all piping, simplifies lifetime maintenance. Compatible with popular EMS software, the units can be remotely controlled and provide detailed LCD diagnostics.
PRODUCT OPTIONS
Dual Fuel Gas Train
- Allows real-time cutover from primary, natural gas operation to propane back-up by rotating a single control valve. No recalibration is necessary;
IRI Gas Train
- Incorporates two safety shut-off valves in a single valve body with normally open vent valve.
Electrical Power
- 220V 1-Phase, 230V 3-Phase or 460V 3-Phase
ACCESSORIES
Gas Supply Regulator
Non-lock-up regulators for gas pressure < 14" W.C.
Lock-up regulators for gas pressures > 14" W.C.
Secondary Low Water Cut-Off (LWCO)
- where required by building code. Secondary LWCO must be installed external to boiler.
CONTROLS
AERCO C-More™ Control Package
- Standard controller supports constant set point, remote set point and/or outdoor reset schedule for individual boiler operation. Offers step-by-step diagnostic menus and status displays to help users set controls and check faults. More than 40 distinct messages, written in easy-to-understand language, convey subsystem status throughout the start-up sequence and during operation. The flash-upgradeable platform can be remotely monitored, controlled and upgraded via Modbus protocol using the RS-232 or RS-485 connection . The system provides failsafe and independent operation in the event of external building control system failures.
Communications Gateway
- optional accessory supports boiler or BMS integration with BACnet, LonWorks and N2 systems.
AERCO BMS
- optional multiple unit controller recommended for installations of two or more boilers to maximize operating efficiency.
Specifications
File Type
View
Save
File Type
View
Save
Natural Gas Specifications
.doc
•
•
Dual Fuel Specifications
.doc
•
•
Literature
File Type
View
Save
File Type
View
Save
Benchmark 2.0 Tech Data Sheet
.pdf
•
•
Product Brochure
.pdf
•
•
Efficiency Curves
.doc
•
•
Sizing & Design Guidelines
File Type
View
Save
File Type
View
Save
Venting & Combustion Air Guide (GF-2050)
.pdf
•
•
Benchmark Application Guide
.pdf
•
•
BMK 2.0 Standard Gas Components & Supply Design Guide (GF-2030)
.pdf
•
•
Electrical Power Wiring Guide
.pdf
•
•
Certifications/Approvals
File Type
View
Save
File Type
View
Save
MEA Number Letter
.pdf
•
•
UL Approval Letter
.pdf
•
•
CSD-1 Compliance Letter
.pdf
•
•
Standard Warranty
File Type
View
Save
File Type
View
Save
Benchmark Warranty
.pdf
•
•
Product & Component Diagrams
File Type
View
Save
File Type
View
Save
Shell Side Pressure Drop
.pdf
•
•
Secondary External Low Water Cut-Off (optional)
.pdf
•
•
Secondary External Low Water Cut-Off - Associated Wiring Diagram
.pdf
•
•
BMS Wiring Diagram - using PWM
.pdf
•
•
BMS Wiring Diagram - using RS-232
.pdf
•
•
BMS Wiring Diagram - using RS-485 only
.pdf
•
•
BMS Wiring Diagram - with CCP
.pdf
•
•
BMK Bill of Materials
.pdf
•
•
.dwg
•
•
Burner Parts & Accessories -
.pdf
•
•
Dimensional Drawing
.pdf
•
•
.dwg
•
•
Pressure Relief Valve
.pdf
•
•
.dwg
•
•
Condensate Trap
.pdf
•
•
Supply Gas Regulators
Maxitrol RV-91 8" to 14"WC inlet pressure
.pdf
•
•
.dwg
•
•
Jeavons J48 2" NPT 14" WC to 1 PSI inlet pressure
.pdf
•
•
.dwg
•
•
Jeavons J48 1 1/2" NPT 1 to 2 PSI inlet pressure
.pdf
•
•
Optional Gas Trains
Dual Fuel Gas Train
.pdf
•
•
.dwg
•
•
IRI Gas Train
.pdf
•
•
.dwg
•
•
Dual Fuel and IRI Gas Train
.pdf
•
•
.dwg
•
•
Controls & Electrical Wiring
File Type
View
Save
File Type
View
Save
Unit Controls
C-More Wiring Diagram - BAS to C-More
.pdf
•
•
.dwg
•
•
C-More Tech Data Sheet
.pdf
•
•
Outdoor Air Sensor Kit for Single Unit
.pdf
•
•
.dwg
•
•
Modbus Communications Manual for BMS & C-More
.pdf
•
•
Modbus Wiring Guidelines for BMS & C-More
.pdf
•
•
Electrical Wiring - 220V 1-Phase (Must download both pages)
220V 1-Phase pg. 1 of 2
.pdf
•
•
.dwg
•
•
220V 1-Phase pg. 2 of 2
.pdf
•
•
.dwg
•
•
Electrical Wiring - 230V 3-Phase (Must download both pages)
230V 3-Phase pg. 1 of 2
.pdf
•
•
.dwg
•
•
230V 3-Phase pg. 2 of 2
.pdf
•
•
.dwg
•
•
Electrical Wiring - 460V 3-Phase (Must download both pages)
460V 3-Phase pg. 1 of 2
.pdf
•
•
.dwg
•
•
460V 3-Phase pg. 2 of 2
.pdf
•
•
.dwg
•
•
Control Accessories
File Type
View
Save
File Type
View
Save
BMS Tech Data Sheet
.pdf
•
•
BMS System Header Sensor (included)
.pdf
•
•
BMS Outdoor Air Sensor Kit (accessory)
.pdf
•
•
Installation & Piping Drawings
File Type
View
Save
File Type
View
Save
Anchor Bolt Location
.pdf
•
•
.dwg
•
•
Clearance for Standalone Unit Placement
.pdf
•
•
.dwg
•
•
Clearance for Side-by-Side Unit Placement
.pdf
•
•
.dwg
•
•
Single Unit Installation
.pdf
•
•
.dwg
•
•
Multi-Units Standing Alone
.pdf
•
•
.dwg
•
•
Multi-Units: 2 Side-by-Side, 1 Alone
.pdf
•
•
.dwg
•
•
Multi-Units: 2 sets of 2 Side-by-Side
.pdf
•
•
.dwg
•
•
Combination Heating & DHW
.pdf
•
•
.dwg
•
•
O&M Manuals
File Type
View
Save
File Type
View
Save
BMK2.0 equipped with C-More Controller (GF-110)
.pdf
•
•
Texas Sites with C-More Controller GF-110T
.pdf
•
•
BMK2.0 equipped with Mod-box controller GF-107
.pdf
•
•
BMK2.0 equipped w/C-More Controller June 2010 (GF-110)
.pdf
•
•
Boiler History Lesson Helps University of North Texas Save Money and Energy
Send to a Colleague
Your name:
Colleague's E-mail:
Your message (click here):
Please enter some message text.