Benchmark 1.5 Low NOx Boiler
OVERVIEW

Benchmark 1.5 Low NOx Boiler

Measuring only 79" high x 28" wide x 36" deep, the BMK1.5 LN fits easily through a standard size doorway and occupies a very small footprint. And it fits the most challenging projects as easily as it fits the smallest mechanical rooms.

The BMK1.5 LN boiler supports sealed combustion, ceiling/sidewall venting and low gas pressure applications. Ideal in low flow applications, the unit operates with a small water side pressure drop.

 


Now, even the smallest hydronic projects will be able to cost effectively leverage the fuel savings and operating reliability of a condensing, fully modulating boiler backed by a market-proven design.
Unmatched 20:1 Turndown with Low NOx Emissions
As a condensing boiler, the thermal efficiency of the BMK1.5LN increases when applied in a system that leverages cold return water temperatures. But it's the unit's unmatched 20:1 turndown that really maximizes operating efficiency and seasonal fuel savings.
Click to Enlarge
Click to enlarge


From 75,000 BTU/hr. to its full fire input capacity of 1.5 million BTU/hr., the BMK1.5LN precisely matches fluctuating loads. This incredible range of operation minimizes boiler cycling and eliminates wasteful temperature overshoot. And the operating efficiency of the BMK1.5LN boiler actually increases as the load decreases. In simple terms, at its lowest firing rates (or BTU/hr. inputs), the unit's heat exchanger becomes greatly oversized in proportion to the load - allowing much greater thermal transfer to take place. The means that the BMK1.5LN saves the most energy during part load operations that characterize the majority of the heating season.

And the BMK1.5LN consistently delivers <30ppm NOx at all firing levels making it ideal for environmentally-friendly projects. The unit employs the same Low NOx burner design and proprietary fuel delivery system as the BMK2.0LN.

Compact, Easy-to-Apply Design
Measuring only 79" high x 28" wide x 36" deep, the BMK1.5 LN fits easily through a standard size doorway and occupies a very small footprint. And it fits the most challenging projects as easily as it fits the smallest mechanical rooms.

The BMK1.5 boiler supports sealed combustion, ceiling/sidewall venting and low gas pressure applications. Ideal in low flow applications, the unit operates with a small water side pressure drop and can withstand no flow conditions without damaging the heat exchanger.

From a controls standpoint, the unit's C-More control system can be integrated directly into a facility-wide Building Automation System via Modbus and is fully compatible with AERCO's Boiler Management System II (BMS II) for multiple unit installations.

Performance-Proven Design
Best of all, the BMK1.5LN employs the same parts and technologies that have been performance proven over the past ten years as part of the Benchmark 2.0 boiler line.
Standard Controls Package
The AERCO C-More™ Control Package supports constant set point, remote set point and/or outdoor reset schedule for individual boiler operation. Offers step-by-step diagnostic menus and status displays to help users set controls and check faults. More than 40 distinct messages, written in easy-to-understand language, convey subsystem status throughout the start-up sequence and during operation. The flash-upgradeable platform can be remotely monitored, controlled and upgraded via Modbus protocol using the RS-232 or RS-485 connection. The system provides failsafe and independent operation in the event of external building control system failures.
PRODUCT OPTIONS
Dual Fuel Gas Train – Allows real-time cutover from natural gas to propane by rotating the fuel selector switch and changing of logic sticks.

IRI Gas Train - Incorporates two safety shut-off valves in a single valve body with normally open vent valve.

Reduced NOx Levels - AERCO recommended calibration points can be re-set to support applications that require reduced NOx emissions levels of <12ppm. However, the unit's input rate, performance efficiency and venting requirements will change. Please consult the factory for assistance balancing your efficiency and environmental requirements.

Low Gas Pressure - For applications where the maximum available gas pressure is only 4" W.C., a de-rated configuration of the product is available at 1,750,000 BTU/hr. 
ACCESSORIES
AERCO BMS II - optional multiple unit controller recommended for installations of two or more boilers to maximize operating efficiency.

Communications Gateway - optional accessory supports boiler or BMS integration with BACnet, LonWorks and N2 systems.

AERClean Air FIlter - This system is for use on boilers drawing air directly from the boiler room; it prevents internal component damage by filtering particulates and airborne dust and debris from the combustion air intake.

Secondary Low Water Cut-Off (LWCO) - where required by building code. Secondary LWCO must be installed external to boiler.

Sentinal Products - Compatible with all materials found in a hydronic loop, these chemicals offer overall protection of a heating system from sludge, scale, corrosion, and freeze conditions.
 
Belimo F6... HDU Series 2-way butterfly valves - are designed to meet the needs of HVAC and commercial application requiring bubble tight shut-off for liquids.  Typical applications include boiler isolation, chiller isolation, cooling tower isolation, change-over systems, air handler coil control, bypass and process control applications. 

Controls & Electrical Wiring
File Type View Save File Type View Save
120V 1-Phase Wiring - FM Gas Train .pdf
120V 1-Phase Wiring - IRI Gas Train .pdf
Internal Wiring            
120V 1-Phase Wiring - FM Gas Train .pdf
120V 1-Phase Wiring - IRI Gas Train .pdf
Literature & Performance Data
File Type View Save File Type View Save
Benchmark 1.5 Low NOx Technical Data Sheet .pdf
Efficiency Curves .doc
Controls            
C-More Tech Data Sheet .pdf
Sizing & Application Guidelines
File Type View Save File Type View Save
Benchmark Application Guide (GF-2070) .pdf
Venting & Combustion Air Guide (GF-2050) .pdf
Electrical Power Wiring Guide (GF-2060) .pdf
Gas Components & Supply Design Guide (GF-2030) .pdf
Product & Component Drawings
File Type View Save File Type View Save
BMK1.5LN Bill Of Materials/Parts List .PDF
Dimensional Drawing .pdf .dwg
Pressure Relief Valve .pdf
Secondary External Low Water Cut-Off (optional) .pdf
Condensate Trap Assembly (AP-A-814) .pdf .dwg
Shell Side Pressure Drop .pdf
Benchmark 1.5 Detailed Drawing .dwg
Gas Trains            
Standard Gas Train (Dual Fuel) .pdf
IRI Gas Train .pdf
IRI Gas Train (Dual Fuel) .pdf
3D Models            
Revit Solid 3D Model BMK1.5 LN Dual Fuel w/ FM Gas Train .rfa
Revit Solid 3D Model BMK1.5 LN Dual-Fuel with IRI Gas Train .rfa
Revit Solid 3D Model BMK1.5 LN for Natural Gas .rfa
Installation & Piping Drawings
File Type View Save File Type View Save
Clearance for Standalone Unit Placement .pdf .DWG
Clearance for Side-by-Side Unit Placement .pdf .dwg
Single Unit Installation (SD-A-870) .pdf .dwg
Multi Unit Install (SD-A-868) .pdf .dwg
Multi ZeroSide Clearance Unit Install (SD-A-869) .pdf .dwg
Natural Gas Unit            
Combination Heating & DHW .pdf .dwg
Controls
File Type View Save File Type View Save
C-More Wiring Diagram - BAS to C-More (SD-A-659) .pdf .dwg
Wiring
File Type View Save File Type View Save
Secondary External Low Water Cut-Off - Associated Wiring Diagram .pdf
Specifications
File Type View Save File Type View Save
Dual Fuel Specifications .doc
CI Format Specifications - Nat. Gas .doc
CI Format Specifications - Duel Fuel .doc
Certifications/Approvals
File Type View Save File Type View Save
TCEQ Approval Letter .pdf
MEA Number Letter .pdf
AHRI & IBR Certificate of Performance .pdf
UL Approval Letter .pdf
GAMA Certification - IBR Rating .pdf
MEA Number Letter .doc

Operation & Maintenance
File Type View Save File Type View Save
BMK1.5LN June 2010 (GF-120) .pdf
BMK1.5LN Dual Fuel Jan 2009 (GF-121) .pdf
BMK1.5LN Dual Fuel June 2010 (GF-121) .pdf
BMK1.5LN May 2009 (GF-120) .pdf
BMK1.5LN Mar 2011 (GF-120) .pdf
BMK1.5LN Dual Fuel Mar 2011 (GF-121) .pdf
BMK1.5LN Dual Fuel July 2011 (GF-121) .pdf
BMK1.5LN July 2011 (GF-120) .pdf
Send to a Colleague
Your name:  
Colleague's E-mail:
Your message (click here):